Skip to content

Quality Management#

21.14.119925.0 - 2024-01-05#

Hotfix

  • Issue with Inspection plan/sampling specification card and Number Series (#8017, QME-177) The using of "Assist"-Button to select a number of releated number series was corrected.
  • QS-Bin posting was not prohibited (#8019, QME-180)
    In Bussiness Central version 21, it is possible to debit goods from the QA inspection location via the article item journal. The result is that the existing inspection order cannot be completed. This problem has been fixed.

21.8.83938.0 - 2023-06-26#

Hotfix

  • Remove function "C99000753_OnAfterCopyRouting" (#6251, QME-143) This function was removed to avoid automatically created lines in inspection plan usage after copying a prod. routing.
  • Consider Versions for reduced inspection plans (#6419, QME-149) This topic assure that sample regulations for reduced inspections are also taken from current inspection plan version.
  • Multilevel prod. orders with inspections failed (#6439, QME-151) This topic assure that mulilevel prod. orders can be calculated also if the bin code for subordinated prod. order lines is empty due to missing bin content details.
  • Renumbering of item failed in inspection iten tracking (#6447, QME-153) Missing table relation was added.

21.7.79376.0 - 2023-05-30#

Hotfix

  • "KVSQME - Tracking Mgt" Permissions Error (#5947, QME-133)
  • Error in "procedure InspOrderMgmt_InitInspectionOrder" (#5951, QME-134)
  • Wrong Dimesion Value in Item Journal Line (QM) (#6134, QME-138)

Change

  • Branches für BC21 (#5609)


21.5.69151.0 - 2023-03-27#

Change

  • General performance and stability improvements.

21.5.68829.0 - 2023-03-24#

Hotfix

  • Wrong ApplicationArea in pageextension 5483784 "KVSQMEModuleSetup" (#5514, QME-115)

Change

  • Setup Profile during app installation (#5538, QME-119)

21.4.64877.0 - 2023-03-02#

Hotfix

  • Consider Cross-Docs. on creating whse. put aways (#5265, QME-69)

Change

  • New Codeunit "PublicFunctions"added to allow access to diverse functions in QM module (#5387, QME-101)

21.3.62492.0 - 2023-02-15#

Change

  • report 5483763 "KVSQME - Inspection Order" --> Item Cross Reference (#4769, QME-94)

21.3.60488.0 - 2023-02-02#

Hotfix

  • Error message when calling the document release during the final check (item with item tracking) (#4838, QME-97)

Change - General performance and stability improvements. - Connect to VRM-API using OAuth2

21.0.54146.0 - 2022-12-15#

Hotfix

  • Renumbering of inspection order no. (#4536, QME-86)

Change

  • New Event for Creation of manual inspection required (#4557, QME-90)

21.0.50863.0 - 2022-11-22#

Change

  • Build in Check Registration (#3769, QME-75)

  • Internal Procedure "PostManualJnlCreateInsp" should be public (#4379, QME-70) Function “PostManualJnlCreateInsp” in codeunit “KVSQME - Insp. Order Mgmt.” was set up as public function to allow access to this functions for foreign development.

Hotfix

  • Status change for test equipment (#4241, QME-79) On Using the action "Release" for status change in the equipment card an error accured that the status can't be changed. Due to this a correction has been done, that the status of a equipment can only be changed by the field "Status" in the equipment card. The actions for status changing in the equipment card were marked vor removal in future versions. (Now the system behavior is analog to the standard system behavior in the production bom)